Advertisement
Advertisement
Specialty Balloons
22 products
All Columns
| Compare | Company Name | Product Name | Nominal Pressure (atm) | Rated Burst Pressure (atm) | Guidewire Compatibility (inch) | Size (F) | Sheath Compatibility (F) | Shaft Length (cm) | Balloon Diameters (mm) | Balloon Lengths (cm) |
|---|---|---|---|---|---|---|---|---|---|---|
| Cook Medical | Advance Enforcer 35 | Dependent on nominal pressure of balloon used | Dependent on rated burst pressure of balloon used | 0.035 | – | 6, 7, 8 | 80, 135 | 6, 8, 10, 12 | 4 | |
| Philips | AngioSculpt RX PTCA Scoring Balloon Catheter | 8 | 20 | 0.014 | 6 | 6 | 137 | 2, 2.5, 3, 3.5 | 6, 10, 15 | |
| B. Braun Interventional Systems, Inc. | BIB Catheter | 1–3.5 | 2–7 | 0.035 | 8, 9, 11 | 8, 9, 10, 11, 16 | 110 | 12, 14, 15, 16, 18, 20, 22, 24, 26, 28, 30 | 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5 | |
| TriReme Medical LLC | Chocolate PTCA Balloon Catheter | 10 | 16 | 0.014 | 5 (2–2.5 mm), 6 (3–3.5 mm) | 5 (2–2.5 mm), 6 (3–3.5 mm) | 140 | 2, 2.5, 3, 3.5 | 1, 1.5, 2 | |
| B. Braun Interventional Systems, Inc. | Corodyn A Angiographic Balloon Flotation Catheter | Nominal inflated diameter: 8, 10, 12 mm | Max injection pressure: 650, 700, 900 PSI | – | 5, 6, 7 | – | 50, 60, 80, 90, 110 | 8, 10, 12 | – | |
| B. Braun Interventional Systems, Inc. | Corodyn P1 Monitoring Wedge Pressure Balloon Flotation Catheter | Nominal inflated diameter: 8, 10, 12 mm | Max. balloon inflation capacity: 0.75, 1.25, 1.5 mL | 0.025, 0.038 | 5, 6, 7 | – | 60, 110 | 8, 10, 12 | – | |
| Cordis | Flash Mini Ostial System | 9 (3–4.5 mm) | 20 (3–4.5 mm) | 0.014 | 6 (3–4.5 mm) | 5 (3–4.5 mm) | 135 | Distal: 3, 3.5, 4, 4.5; proximal: 9 | Distal: 8; proximal: 0.9 | |
| Cordis | Flash Ostial System | 8 (5–7 mm), 9 (4, 4.5 mm) | 12 (5–7 mm), 20 (4–4.5 mm) | 0.014 (4–7 mm), 0.035 (7 mm) | 6 (4–6 mm), 7 (7 mm), 8 (7 mm, 0.035 inch) | 5 (4–6 mm), 6 (7 mm) | 135 | Distal: 4, 4.5, 5, 6, 7; proximal: 12.6 | Distal: 12, 17; proximal: 1.3 | |
| B. Braun Interventional Systems, Inc. | Mini Ghost PTA Catheter | Up to 10 | Up to 20 | 0.018 | 3.5 | 4 | 40, 80, 120, 150 | 2, 3, 4, 5, 6 | 1, 2, 3, 4, 6, 8, 10 | |
| Teleflex | Pantera Lux | 7 | 12–13 | 0.014 | – | – | 140 | 2–4 | – | |
| Teleflex | Passeo-14 | 7 | 14 | 0.014 | – | – | 20–220 | 1.5–4 | – | |
| Teleflex | Passeo-18 | 6 | 12–15 | 0.018 | – | – | 20–200 | 2–7 | – | |
| Teleflex | Passeo-35 | – | – | 0.035 | – | – | – | – | – | |
| B. Braun Interventional Systems, Inc. | PTS Sizing Balloon | Up to 0.75 | Up to 1.5 | 0.035 | – | 8, 9 | 80 | 20, 25, 30, 40 | 3, 4, 5 | |
| B. Braun Interventional Systems, Inc. | PTS-X Sizing Balloon | Up to 0.75 | Up to 1.5 | 0.035 | – | 8, 9 | 80, 110 | 20, 25, 30, 35, 40 | 3, 4, 5 | |
| Abbott (manufactured by OrbusNeich) | Scoreflex NC Scoring PTCA Catheter | 12 | 20 | 0.014 | – | 5 (diameter, 1.75–3.5); 6 (diameter, 0.40) | 140 | 1.75–4 | 10–20 | |
| IMDS | TrapIT 100 | 8 | 12 | – | 2 | – | 111.5 | 2.5 | 1.5 | |
| IMDS | TrapIT 90 | 8 | 12 | – | 2 | – | 101.5 | 2.5 | 1.5 | |
| Boston Scientific Corporation | Wolverine Monorail Cutting Balloon Dilation Device | 6 | 12 | 0.014 (guidewire compatible) | 2.7 | 6 | MR: 142; OTW: 143 | 2, 2.25, 2.5, 2.75, 3, 3.25, 3.5, 3.75, 4 | 6, 10, 15 | |
| Boston Scientific Corporation | Wolverine Over-the-Wire Cutting Balloon Dilation Device | 6 | 12 | 0.014 (guidewire compatible) | 2.7 | 6 | 143 | 2, 2.5, 3, 3.5, 4 | 6, 10, 15 | |
| B. Braun Interventional Systems, Inc. | Z-5 Atrioseptostomy Catheter | – | 1, 2 mL (maximum inflation volume) | 0.014, 0.021 | 4, 5 | 5, 6 | 50 | 9.5, 13.5 | 0.95, 1.35 | |
| B. Braun Interventional Systems, Inc. | Z-6 Atrioseptostomy Catheter | – | 1, 2 mL (maximum inflation volume) | 0.021 | 5 | 6 | 50 | 9.5, 13.5 | 0.95, 1.35 |
Advertisement
Advertisement
We value keeping the Device Guide up to date.
If you want to add or update your company’s device listings, please let us know!
Contact UsBalloons
More Categories:
Balloons Catheters Sheaths Stents Structural Heart Valves Wires Other Devices View AllAdvertisement